Nitrogen Generator 6800
CP Series Cabinet

This system features our patent-pending GENERON® 6800-CP Membrane Modules. These are specially designed for industrial applications to reach higher efficiency at a lower cost by removing the outer shell that our 6800 Modules typically use. This results in a lighter overall design, and simpler integration with our Kwik Connect Manifold system. Maintenance is as easy as removing the side panel and changing out any element.
Reliable nitrogen membranes are the heart of a nitrogen generation system. GENERON® Membrane Modules have been at the forefront of the industry for over 50 years. Our research and development team in California works to continuously improve the performance and durability of our membranes.
After the installation of your new product, we offer you our best customer service team. The GENERON®Parts and Service department provides maintenance and technical support worldwide, and can be reached online or through your GENERON® sales representative.

 

 

Typical Applications:

  • Gas Assisted Injection Molding (GAIM)
  • Heat Treatment of Ferrous & Non-Ferrous Metals
  • Inerting of Flammable Liquids & Gases
  • Food Packaging
  • Laser / Plasma Cutting
  • Re-flow and Wave Soldering of PCBs
  • Brazing
  • Blanketing of Chemical & Pharmaceuticals
  • Auto Clave

 

 

 

 

nitrogen generator rental

Triton 680 Series Nitrogen Generators offer world class features:

  • Generon patented Hollow Fiber Membranes, manufactured in Pittsburg, CA, USA 
    • HMI display scree providing inlet / outlet pressure, system run status and O 2 concentration 
    • Hinged, easy-access front panel and removable side panel 
    • Automatic purity control valve · Integrated sensors · Generon SureLink PLC system 
    • Generon backs its product with an industry leading 2-year warranty

 

The Triton 6150 Series Cabinet simple design delivers reliable nitrogen

Nitrogen purities from 95% to 99.5%

Flow rates from 300 scfh to 24,440 scfh

Manufactured with Generon patented Hollow Fiber Membranes

 

General Characteristics Rated Capacity (scfh) @ 95% – 99.5% 300 – 24,440
Absorbed power (watts) 400 – 800
Power supply (VAC / hz) 120 / 60
Operating Limits Design operating pressure range (psig) 50 – 200
Design operating temperature range (°F) 50 – 131
Recommended operating temperature range (°F) 70 – 120
Membrane Material Construction Uncased
Membrane Type Hollow Fiber Membrane
Controls & Design Generator design Cabinet Enclosure
Controller type Programmable Logic Controller (PLC) available
Interface type (HMI) Color Touchscreen available
Electrical rating For Indoor / Safe Area Installation
Connections Compressed air inlet NPT – Size Varies
Permeate NPT – Size Varies
Nitrogen outlet NPT – Size Varies
*Standard conditions: Feed temperature @ 80°F, feed pressure of 110 psig at sea level.
Flow pressure values are averages with tolerances of +/- 3%.
Standard design characteristics have no heater included.